Bio Rad Slot Blot Apparatus

Bio Rad Slot Blot Apparatus Average ratng: 3,6/5 3251 votes

Overview

  1. Bio Rad Dot Blot Apparatus Manual
  2. Bio Rad Slot Blot Apparatus Test
  3. Slot Blot Protocol
  4. Slot Blot Hybridization

Western blotting is a widely used technique by research and clinical labs to detect proteins with their specific antibody. Blots require an apparatus, or blotter to transfer the gel to membrane under wet, dry or semi-dry conditions. Transfer protocol depends on type of protein, gel thickness, and type of membrane.

Bio rad slot blot apparatus wow
  • Bio-Rad Protocol Makeover.
  • The 96-well Bio-Dot ® and 48-well Bio-Dot SF (slot format) microfiltration units provide easy, reproducible methods for binding proteins or nucleic acids in solution onto membranes. Many experimental protocols can be accommodated by using interchangeable templates.
ApparatusBio rad slot blot apparatus test

Test blots, as their name implies, are very simple Western blots that are created for the express purpose of optimizing or troubleshooting experimental conditions. They are usually produced by running multiple lanes of the same lysate or purified protein solution on a gel, and after transfer cutting the blot into strips to be tested individually.

They provide a quick and efficient means of examining a range of antibody dilutions or detection substrates

Dot blots and slot blots are also a very useful variation on the typical Western blot. They do not require gel electrophoresis, so there is no separation of proteins by size.

Instead, the target protein or cell lysate mixture is added directly onto the surface of the nitrocellulose or PVDF membrane. Protein solutions can be applied directly in a small volume, or with a vacuum manifold to produce an orderly grid of samples similar to that seen in Figure 14. Each dot or slot blot would contain known amounts of target protein or cell lysate.

Once dry, dot blots and slot blots are subjected to the same immunodetection steps used for Western blotting, i.e. blocking, antibody incubation, and target detection with substrate. Grey and black spots on the figure below indicate which samples are positive for the target protein and correspond roughly to the bands produced on a Western blot.

Bio Rad Dot Blot Apparatus Manual

Figure 14: Dot Blots and Slot Blots. The dot blots at the left represent a dilution series of a sample, with smaller lighter dots corresponding to lower concentrations of target protein. The slot blots represent a group of random samples, the intensity of the signal corresponds to the concentration of the target protein in that sample.

Bio Rad Slot Blot Apparatus Test

By making a number of identical dots or slots of a single known protein sample, or a range of sample dilutions, one can quickly test several combinations and concentrations of primary and secondary antibodies. Dot blots and slot blots are also beneficial when screening a large number of samples, or if a simple answer will suffice.

Slot

Slot Blot Protocol

The main downside to slot blots/dot blots is that they provide no information about molecular weight. Thus, it is harder to detect false positive signals, or to tell whether modified forms of a protein are present.

Slot Blot Hybridization

Detection with Substrate Chapter 4: Data Analysis